The IEC standard corresponding to GB/T3836-2021 standard

SINO Testing Services

| 2022-06-27|Return

With the release and implementation of the new version of the national standard GB/T3836-2021, domestic explosion-proof standards have further aligned with international explosion-proof standards. The new version of the national explosion-proof standard combines the original GB12476 and GB25286 standards, covering various aspects such as design, manufacturing, inspection, selection, installation, inspection, maintenance, repair, and site classification of equipment used in explosive environments. It adopts a segmented standard form, including but not limited to the following parts.

GB/T 3836.1-2021 Explosive Atmosphere Part 1: General Requirements for Equipment

Corresponding IEC standards: IEC 60079-0: 2017 Explosive Atmosphere Part 0: General Requirements for Equipment

GB/T 3836.2-2021 Explosive Atmosphere Part 2: Equipment Protected by Flameproof Enclosures "d"

Corresponding IEC standards: IEC 60079-1: 2014 Explosive Environments Part 1: Equipment Protected by Explosion proof Enclosures "d"

GB/T 3836.3-2021 Explosive Atmosphere Part 3: Equipment Protected by Increased Safety Type "e"

Corresponding IEC standards: IEC 60079-7: 2015 Explosive Atmosphere Part 7: Equipment Protected by Increased Safety Type "e"

GB/T 3836.4-2021 Explosive Atmosphere Part 4: Equipment Protected by Intrinsic Safety Type "i"

Corresponding IEC standards: IEC 60079-11: 2011 Explosive Atmosphere Part 11: Equipment Protected by Intrinsic Safety Type "i"

GB/T 3836.5-2021 Explosive Atmosphere Part 5: Equipment Protected by Positive Pressure Housing "p"

Corresponding IEC standards: IEC 60079-2: 2014 Explosive Atmosphere Part 2: Equipment Protected by Positive Pressure Shell "p"

GB/T 3836.6-2017 Explosive Atmosphere Part 6: Equipment Protected by Liquid Immersion Type "O"

Corresponding IEC standards: IEC 60079-6: 2015 Explosive Atmosphere Part 6: Equipment Protected by Liquid Immersion Type "O"

GB/T 3836.7-2017 Explosive atmospheres - Part 7: Equipment protected by sand filled molds "q"

Corresponding IEC standards: IEC 60079-5: 2015 Explosive Atmosphere Part 5: Equipment protected by sand filled mold "q"

GB/T 3836.8-2021 Explosive Atmosphere Part 8: Equipment Protected by "n" Type

Corresponding IEC standards: IEC 60079-15: 2017 Explosive Atmosphere Part 15: Equipment Protected by "n" Type

GB/T 3836.9-2021 Explosive Atmosphere Part 9: Equipment Protected by Sealed Type "m"

Corresponding IEC standards: IEC 60079-18: 2014 Explosive Atmosphere Part 18: Equipment Protected by Sealed Type "m"

GB/T 3836.11-2017 Explosive Atmosphere Part 11: Classification Test Methods and Data for Characteristics of Gas and Vapor Substances

Corresponding IEC standards: IEC 60079-20-1: 2010 Explosive Atmosphere Part 2-1: Classification Test Methods and Data for Gas and Vapor Substances Characteristics

GB/T 3836.12-2019 Explosive Atmosphere Part 12: Test Methods for Characteristics of Combustible Dust Substances

Corresponding IEC standards: ISO/IEC 80079-20-2: 2016 Explosive Atmosphere Part 20-2: Material Characteristics Combustible Dust Test Method

GB/T 3836.13-2021 Explosive Atmosphere Part 13: Equipment Repair, Maintenance, Restoration and Modification

Corresponding IEC standards: IEC 60079-19: 2019 Explosive Environment Part 19: Repair, Maintenance, and Restoration of Equipment

GB 3836.14-2014 Explosive Atmosphere Part 14: Site Classification Explosive Gas Atmosphere

Corresponding IEC standards: IEC 60079-10-1: 2008 Explosive Atmosphere Part 10-1: Classification of Hazardous Areas Explosive Gas Atmosphere

GB/T 3836.15-2017 Explosive Atmosphere Part 15: Design, Selection and Installation of Electrical Installations

Corresponding IEC standards: IEC 60079-14: 2007 Explosive Atmosphere Part 14: Design, Selection, and Installation of Electrical Installations

GB/T 3836.16-2017 Explosive Atmosphere Part 16: Inspection and Maintenance of Electrical Installations

Corresponding IEC standards: IEC 60079-17: 2007 Explosive Atmosphere Part 16: Inspection and Maintenance of Electrical Installations

GB/T 3836.17-2019 Explosive Atmosphere Part 17: Equipment Protected by Positive Pressure Room "p" and Artificially Ventilated Room "v"

Corresponding IEC standards: IEC 60079-13: 2017 Explosive Atmosphere Part 13: Equipment Protected by Positive Pressure Room "p" and Artificially Ventilated Room "v"

GB/T 3836.18-2017 Explosive Atmosphere Part 18: Intrinsically Safe Electrical Systems

Corresponding IEC standards: IEC 60079-25: 2010 Explosive Atmosphere Part 25: Intrinsically Safe Electrical Systems








Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號
Service Hotline
18924609560
點擊這里給我發消息 1354407946
點擊這里給我發消息 1354407946
主站蜘蛛池模板: 久久国产视频网站 | 最新国产中文字幕 | 成人久久18 | 天天干,夜夜操 | 男人天堂手机在线视频 | 国产精品不卡视频 | 精品久久一区 | 国产精品美女视频免费观看软件 | 欧美激情网站 | 日韩免费看 | 国产精品国色综合久久 | 久久久久久久久久久久久久久久久久久 | 欧美一区2区 | 色综网| 国产激情视频一区 | 久久久免费观看视频 | 在线日韩欧美 | 曰韩毛片 | 国产成人精品免高潮在线观看 | 亚洲日本国产 | 精品一区视频 | 在线色 | 精品国产青草久久久久福利 | 日韩在线欧美 | 亚洲一区二区三区在线视频 | 精品国产乱码久久久久夜 | 日韩精品无码一区二区三区 | 在线中文字幕av | 成人精品一区二区三区 | 99久久99 | 国产精品乱码一区二区三区 | 亚洲精品电影网在线观看 | 欧美精品在线一区二区三区 | 国产午夜视频在线观看 | 成人在线播放网站 | 国产成人综合在线 | 日韩激情综合网 | 亚洲国产精品人人爽夜夜爽 | 国产高清精品一区 | 欧美精品在欧美一区二区少妇 | 国产精品成人网 |