The use of explosion-proof electrical equipment in explosive hazardous areas is the most basic safety requirement. However, due to factors such as personnel, equipment, and environment involved in the selection, installation, use, and maintenance of explosion-proof electrical equipment, it is easy to cause explosion-proof electrical equipment to fail or explode. Therefore, it is necessary to conduct regular and irregular safety inspections and maintenance on the explosion-proof electrical equipment used.

So, from which aspects should we confirm the explosion-proof safety performance of explosion-proof electrical equipment?

1. Personnel

AQ 3009-2007 "Code for Electrical Safety and Explosion Protection in Hazardous Areas" clearly stipulates that the inspection and maintenance of explosion-proof electrical equipment should be carried out by professional personnel who meet the prescribed conditions. These personnel should undergo business training, including various explosion-proof types, installation practices, relevant regulations and rules, as well as general principles of hazardous area classification. They should also receive appropriate continuing education or regular training, and possess relevant professional experience and qualification certificates, in order to improve their level of selection, installation, use, maintenance, overhaul and management of explosion-proof electrical equipment.

2. Selection

Explosion proof electrical equipment should be selected based on the level of the explosion hazardous area and the category, level, and group of explosive hazardous substances, and follow the principles of safety, reliability, and economic rationality. Special attention should be paid to the selection of mobile explosion-proof electrical equipment, as well as the relocation of explosion-proof electrical equipment in use, changes in process equipment or materials, and full consideration should be given to the explosion-proof electrical equipment and its usage environment, and it should be adapted accordingly.

3. Procurement

When purchasing explosion-proof electrical equipment, suppliers must be required to provide valid explosion-proof qualification certificates, and special attention should be paid to equipment with explosion-proof qualification certificate numbers ending with the letters "U" or "X". Full consideration should be given to the special requirements of the usage environment for explosion-proof electrical equipment, such as corrosion, high temperature, etc. The model, specifications, and explosion-proof markings of explosion-proof electrical equipment should meet the design requirements, and technical documents, attachments, and spare parts should be complete and complete. For explosion-proof electrical equipment purchased in bulk, a nationally recognized explosion-proof inspection agency can be commissioned to conduct sampling inspections.

4. Installation acceptance

The installation of explosion-proof electrical equipment and electrical circuits should be carried out in accordance with relevant national standards and regulations.

The type, level, group, environmental conditions, and usage conditions of explosion-proof electrical equipment should comply with the design specifications; The laying method and path selection of electrical circuits should also comply with the design regulations.

The wiring engineering of intrinsically safe electrical equipment must not only be constructed according to the design requirements, but also comply with the relevant provisions of the product technical documents.

After installation, acceptance should be carried out in accordance with the construction acceptance specifications, and an explosion-proof electrical equipment file should be established (including explosion-proof electrical equipment ledger, copies of explosion-proof certificates, user manuals, inspection records, maintenance records, etc.).

5. Check

Inspection is a non dismantling or partial dismantling activity carried out to obtain the operating status of equipment, determine whether the equipment is safe and reliable, and supplemented by some testing measures. Explosion proof electrical equipment, systems, and installations should undergo initial inspection before being put into operation; Regular routine inspections should be conducted during operation. Initial and regular inspections should be entrusted to safety production testing and inspection institutions with explosion-proof professional qualifications, and the interval between regular inspections should generally not exceed 3 years.

6. Continuous supervision

Continuous supervision is the regular maintenance, inspection, management, and monitoring of electrical equipment by experienced technical personnel in professional installation and usage environments, in order to maintain the explosion-proof performance of the equipment in good condition. Continuous supervision is one of the important links in the safety management of explosion-proof electrical equipment throughout its entire life cycle. Professional personnel in enterprises should conduct continuous supervision as required and keep corresponding inspection records. For any abnormal phenomena (faults or changes) found, timely measures should be taken or subsequent repairs should be carried out.

7. Maintenance

Maintenance is a comprehensive activity that maintains or restores a product to a state that meets relevant technical requirements and achieves its required functions.

Maintenance activities should pay attention to maintaining the integrity of the explosion-proof type of equipment, and replacement of components (such as bolts, screws, and similar components related to explosion-proof types) should be carried out in accordance with the requirements of relevant safety documents. Any components that have a negative impact on the safety performance of the equipment should not be replaced without the consent of relevant departments.

8. Maintenance

When explosion-proof electrical equipment experiences a decrease or failure in explosion-proof performance due to external chemical corrosion, mechanical wear, natural aging, etc., maintenance should be carried out. Maintenance should be carried out in accordance with the relevant provisions of GB3836.13-2013 "Explosive Atmosphere Part 13: Equipment Repair, Maintenance, Repair and Modification". After maintenance, inspection should be carried out. If the explosion-proof performance of the original level cannot be restored after maintenance, the explosion-proof level can be reduced or used as non explosion-proof electrical equipment.

9. Invalid scrapping

When the structure and parameters of explosion-proof electrical equipment change and do not match the original explosion-proof type and design, and cannot be repaired, it is judged as invalid and immediately stopped for replacement. For those that cannot meet the explosion-proof performance after repair, they should be judged as ineffective. Establish a system for scrapping explosion-proof electrical equipment that has failed, and prohibit the use of expired explosion-proof electrical equipment in hazardous areas

 

Establish a full life cycle safety management system for explosion-proof electrical equipment, achieve scientific, standardized, and standardized safety management of in use explosion-proof electrical equipment, and ensure the safe and stable operation of explosion-proof electrical equipment.


Service Hotline: 18924609560 (same WeChat account)


Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號(hào)
Service Hotline
18924609560
點(diǎn)擊這里給我發(fā)消息 1354407946
點(diǎn)擊這里給我發(fā)消息 1354407946
主站蜘蛛池模板: 欧美日韩午夜精品 | 一级在线观看 | 欧美日韩一区二区三区在线观看 | 久久va| 视频一区二区中文字幕日韩 | 色视频久久 | 一级片手机免费看 | 欧美一区二区免费 | 日韩中文字幕在线观看 | 浴室洗澡偷拍一区二区 | 日韩视频免费在线观看 | 97超碰免费在线 | 欧美国产三级 | 久久精品国产99国产 | 久久亚洲国产精品日日av夜夜 | 亚洲乱码一区二区三区在线观看 | 全黄大全大色全免费大片 | 国产精品免费在线 | 亚洲一区二区三区四区在线观看 | 国产视频99| 国内精品一区二区 | 国产一区免费在线观看 | 午夜成人在线视频 | 欧美日韩免费看 | 手机看片福利一区 | 国产精品毛片久久久久久久av | 午夜视频在线播放 | 久草在线高清 | 波多野结衣中文字幕在线视频 | 亚洲自拍偷拍第一页 | 欧美久久成人 | 日韩大尺度在线观看 | 亚洲精品久久久久久久久久久久久 | 欧洲一级免费 | 亚洲成人一区二区三区 | 97电影在线观看 | 手机看片福利视频 | 男人的天堂在线视频 | 欧美日韩中文字幕在线播放 | 亚洲三级网 | 在线观看日韩 |